Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
PLoS One ; 15(12): e0244963, 2020.
Article in English | MEDLINE | ID: covidwho-999852

ABSTRACT

The COVID-19 pandemic disrupted the world in 2020 by spreading at unprecedented rates and causing tens of thousands of fatalities within a few months. The number of deaths dramatically increased in regions where the number of patients in need of hospital care exceeded the availability of care. Many COVID-19 patients experience Acute Respiratory Distress Syndrome (ARDS), a condition that can be treated with mechanical ventilation. In response to the need for mechanical ventilators, designed and tested an emergency ventilator (EV) that can control a patient's peak inspiratory pressure (PIP) and breathing rate, while keeping a positive end expiratory pressure (PEEP). This article describes the rapid design, prototyping, and testing of the EV. The development process was enabled by rapid design iterations using additive manufacturing (AM). In the initial design phase, iterations between design, AM, and testing enabled a working prototype within one week. The designs of the 16 different components of the ventilator were locked by additively manufacturing and testing a total of 283 parts having parametrically varied dimensions. In the second stage, AM was used to produce 75 functional prototypes to support engineering evaluation and animal testing. The devices were tested over more than two million cycles. We also developed an electronic monitoring system and with automatic alarm to provide for safe operation, along with training materials and user guides. The final designs are available online under a free license. The designs have been transferred to more than 70 organizations in 15 countries. This project demonstrates the potential for ultra-fast product design, engineering, and testing of medical devices needed for COVID-19 emergency response.


Subject(s)
COVID-19/therapy , Equipment Design/methods , Respiration, Artificial/instrumentation , Ventilators, Mechanical/adverse effects , Animals , COVID-19/pathology , Humans , Respiration, Artificial/methods , Respiratory Mechanics/physiology , Respiratory Rate/physiology , SARS-CoV-2 , Swine
2.
IEEE Trans Biomed Circuits Syst ; 14(5): 1088-1096, 2020 10.
Article in English | MEDLINE | ID: covidwho-737835

ABSTRACT

In response to anticipated shortages of ventilators caused by the COVID-19 pandemic, many organizations have designed low-cost emergency ventilators. Many of these devices are pressure-cycled pneumatic ventilators, which are easy to produce but often do not include the sensing or alarm features found on commercial ventilators. This work reports a low-cost, easy-to-produce electronic sensor and alarm system for pressure-cycled ventilators that estimates clinically useful metrics such as pressure and respiratory rate and sounds an alarm when the ventilator malfunctions. A low-complexity signal processing algorithm uses a pair of nonlinear recursive envelope trackers to monitor the signal from an electronic pressure sensor connected to the patient airway. The algorithm, inspired by those used in hearing aids, requires little memory and performs only a few calculations on each sample so that it can run on nearly any microcontroller.


Subject(s)
Clinical Alarms , Coronavirus Infections/therapy , Monitoring, Physiologic/instrumentation , Pneumonia, Viral/therapy , Respiration, Artificial/instrumentation , Signal Processing, Computer-Assisted , Ventilators, Mechanical , Algorithms , COVID-19 , Electronics , Equipment Design , Humans , Pandemics , Respiration , Software
SELECTION OF CITATIONS
SEARCH DETAIL